The TRANBERG® TEF 9202 is a lightweight, compact self-regulating enclosure heater in flame-retardant composite (UL 94 V-0) for Zone 1, Zone 2 and safe area. At 0.56–0.76 kg and 180 × 300 × 30 mm it fits where a steel heater is too large or too heavy, and the self-regulating element reduces its output as the ambient temperature rises, so it cannot overheat. Supplied with a 1.5 m flying lead and, optionally, a DIN rail bracket that can be fitted horizontally or vertically. Developed and manufactured at our own factory.
Two versions
T4 (TPS5559) in 240 V or 120 V for mounting inside an enclosure rated IP54 or higher, and T3 with IP66 (TPS6334) in 240 V for use where the heater itself must be sealed. Both are available as 50 W and 100 W, nominal at still air and 0 °C.
Application
- Inside equipment enclosures and cabinets, to prevent condensation and provide climatic control
- Frost protection and temperature maintenance
- Anti-condensation in Zone 1, Zone 2 and safe area
Features and benefits
- Lightweight composite structure, compact and easy to install
- Corrosion proof, fire retardant UL 94 classification V-0
- Self-regulating heating element, prevents overheating
- Low inrush current
- Can be supplied with DIN rail module
- Low maintenance
Technical data (TPS5559 / TPS6334)
| Ex protection | T4: II 2G Ex 60079-30-1 IIC T4 Gb; T3: II 2G Ex eb IIC T3 Gb |
|---|---|
| Nominal voltage | T4: 100/240 V 50/60 Hz (120 V and 240 V variants); T3: 240 V 50/60 Hz |
| Nominal output | 50 W or 100 W at still air, 0 °C |
| Material | Composite, UL 94 V-0 |
| Ingress protection | T4: for use in enclosures with min. IP54; T3: IP66 |
| Operational ambient temperature | −50 °C to +50 °C |
| Max. withstand ambient temperature | +50 °C energised, +80 °C de-energised |
| Electrical connection | Flying lead 1.5 m, 2 × 2.5 mm² + PE |
| Inrush current (T3) | Approx. 2 A |
| Dimensions | 180 × 300 × 30 mm, mounting 140 × 201 mm |
| Weight | 0.56 kg (50 W), 0.76 kg (100 W) |
Approvals and certificates
- T4: CML 22ATEX3623X, IECEx CML 22.0096X
- T3: Presafe 18ATEX12634X, IECEx PRE 18.0037X
- Datasheets, drawings, certificates and user manuals are listed above the table
Installation notes
The supply circuit shall include an electrical protection device according to IEC/EN 60079-30-1 clause 4.3. The unterminated flying lead must be terminated in an Ex e junction box.
Accessories
DIN rail bracket SS35/7.5 (part no. 50520075) for horizontal or vertical mounting on a DIN rail, and an external JUMO ExTherm-AT capillary thermostat (part no. 50295391, datasheet TTD6717). Ask us for a quote together with the heater.