Solutions

Products for marine, energy and aviation

Ex-certified equipment, heat tracing systems and marine lighting, designed and built at our own factory in Norway. Choose an area to see the product groups, or go straight to downloads for brochures and certificates.

  • ATEX, IECEx and DNV MED
  • Own factory and R&D
  • Distributors in 40+ countries
  • Datasheets on every product page

How we help

More than the products

Project management

Sizing, lighting and heat loss calculations, documentation for class and commissioning.

Project management →

Own factory

Designed, built and tested under one roof, with short delivery times and room for changes.

Own factory →

Datasheets and certificates

Datasheets, Ex certificates, declarations of conformity and STEP files are on every product page.

Datasheets and certificates →

Talk to an engineer

Send us the drawings or the equipment list and we propose a solution, part numbers and documentation.

27 part numbersIP 66/67LEDSeawater resistant aluminium
View part numbers

Compact LED floodlight for area lighting on ships and smaller vessels: 5000 lumen at 40 W, IP66/67, seawater-resistant C5M powder-coated aluminium with glass front and AISI 316L bracket, M25 QPD quick plug, sealed for life. Narrow, medium or wide light distribution in 2200 K, 4000 K or 5000 K, 200–240 V AC or 24 V DC, standard or DALI. 27 part numbers – select by version below.

2 part numbersIP56LEDStainless Steel
View part numbers

LED searchlight replacing the 2000 W halogen: 84 LEDs, 30 000 lm, 4.75 Mcd, 4.3° beam, approx. 2 000 m at 1 lux, 1.5 A at 230 V, IP56, RS-485 network control. Standard or hanging mounting – select below.

25 part numbersIP66230 V 50/60 HzAISI 316L
View part numbers

Self-regulating Ex enclosure heater in stainless steel AISI 316L for Zone 1, Zone 2 and safe area, IP66, 230 V. 100–1000 W with flying lead, junction box, or junction box and ambient thermostat (+5 or +15 °C). 25 part numbers – select by connection and output below.

20 part numbersIP 66/67LEDSeawater resistant aluminium
View part numbers

Compact LED floodlight for area lighting on ships and smaller vessels: 10 000 lumen at 77 W, IP66/67, seawater-resistant C5M powder-coated aluminium with glass front and AISI 316L bracket, M25 QPD quick plug, sealed for life. Narrow, medium or wide light distribution in 2200 K, 4000 K or 5000 K, 200–240 V AC, standard or DALI. 20 part numbers – select by version below.

7 part numbersIP56XenonStainless Steel
View part numbers

Long-range xenon searchlight in stainless steel with HBX power supply: 1000 to 3000 W, 40 to 91 Mcd, 6 700 to 11 500 m at 1 lux, motor focus 2–8°, IP56, −50 °C, RS-485 network control. The preferred searchlight for ice navigation. Four part numbers – select below.

16 part numbersFor enclosures min. IP54230 V 50/60 HzAISI 316L
View part numbers

Self-regulating Ex enclosure heater in stainless steel AISI 316L, temperature class T4, for enclosures rated IP54 or higher in Zone 1, Zone 2 and safe area. 230 V, 50–600 W with flying lead, junction box, or junction box and ambient thermostat (+5 or +15 °C). 16 part numbers – select by connection and output below.

38 part numbersIP 66Stainless steel AISI 316L
View part numbers

Ex e enclosures in brushed stainless steel AISI 316L from R. STAHL series 8150, delivered with Ex certificate: empty enclosures with hinged or screwed lid in 20 sizes, and instrument and telecom enclosures with vertical terminal rails for 4 to 24 pairs, non-IS or intrinsically safe. IP66. 40 part numbers – select by enclosure type below.

7 part numbersIP56HalogenStainless Steel
View part numbers

Stainless steel halogen searchlight for professional vessels: 1000 W with 305 mm mirror or 2000 W with 450 mm mirror, with or without motor focus, IP56, controlled over RS-485 from TEF 2612/2613 panels. Five part numbers – select below.

31 part numbersIP66/67LEDAnodised aluminium
View part numbers

Compact 15 W LED luminaire for walkways, car decks, engine rooms and cargo areas: anodised aluminium, IP66/67, 1.5 kg, 50 000 h, Phoenix QPD quick plugs. 100–240 V AC or 24 V DC in 2200, 4000 and 5000 K, plus blue signal light. 31 versions – select below.

1 part numbers
View part numbers

Brass thread adaptor from M25 male to M28×1 female, 9 mm thread length, for fitting M28×1 hose parts to an M25 entry.

1 part numbersAISI 316L
View part numbers

Swivel adaptor connecting the AISI 316 flexible hose to the M28×1 transition unit on wall mounted heat trace junction boxes.

1 part numbers
View part numbers

90° mounting bracket in stainless steel 316 for the TEF 2880 navigation light and the TEF 2785 BlueLine luminaire, with the TEF 2850/2870 hole pattern so it fits existing drillings when older lanterns are replaced.

1 part numbers
View part numbers

Replacement bushing for the pivot of the searchlight arms on TRANBERG® searchlights.

1 part numbersBrass
View part numbers

Ex e brass gland M25 with M28×1 adaptor for the flexible hose and silicone grommets for heating cables.

1 part numbers
View part numbers

Protective canvas cover for the 1000 W and 2000 W halogen searchlights TEF 2620, 2630, 2640 and 2650, for use when the searchlight is not in operation. 2 kg.

1 part numbers
View part numbers

Protective canvas cover for the 457 mm xenon searchlights TEF 2650 2000 W and 3000 W and the Suez searchlight, for use when the searchlight is not in operation. 2 kg.

1 part numbers
View part numbers

Caution label marking the position of a heating cable splice under the insulation. Norwegian and English text.

1 part numbers
View part numbers

Caution label marking the position of a heating cable end seal under the insulation. Norwegian and English text.

1 part numbers
View part numbers

Caution label warning that the pipe or vessel is electrically heat traced. Norwegian and English text. Fitted on the insulation cladding at regular intervals.

1 part numbers
View part numbers

Stainless steel clamp holding two self-regulating heating cables of 5 × 15 mm, or Ø 10 mm cable, against the pipe or structure. 0.2 kg. Drawing 784A109624.

20 part numbersAISI 316L
View part numbers

Hinged standard-duty trefoil cable cleat in stainless steel 316L to IEC 61914, with LSF/LS0H liners and short-circuit withstand up to 135 kA peak. 20 sizes for cable diameters 19–103 mm – select below.

10 part numbersAISI 316L
View part numbers

Hinged heavy-duty cable cleat in stainless steel 316L for single and parallel cables to IEC 61914, LSF/LS0H liners, up to 110 kA peak / 50 kA RMS, −60 to +60 °C. 10 sizes for cable diameters 19–120 mm – select below.

1 part numbers
View part numbers

Gateway that connects the RS-485 Commander searchlight network to a ship or platform system over Modbus TCP, for remote control and position monitoring of up to eight searchlights.

1 part numbers
View part numbers

Gateway with RS-422 port giving an external computer control and position feedback of up to eight Commander searchlights, using ASCII commands on a proprietary NMEA-0183 based protocol.

1 part numbersAISI 316L+ Bras
View part numbers

Wall mounting connection kit that brings the PT100 sensor cable (Ø4.5–9.1 mm) into the thermostat or junction box.

1 part numbersIP 66/67Aluminium
View part numbers

Ex-certified aluminium control cabinet supplying and monitoring the TEF 9980 main and repeater status lights, 100–240 V AC, IP66/67, for installation in Zone 1 or Zone 2.

1 part numbers66100 ... 240 V AC
View part numbers

Powder-coated sheet steel control cabinet for safe-area control rooms, supplying and monitoring the TEF 9980 main and repeater status lights, 100–240 V AC. 18 kg.

1 part numbersIP66Brass
View part numbers

Ex e certified drain and breather plug M25 in brass with lock nut, for heat trace junction boxes and thermostats. IP66.

1 part numbersBras+AIS I316
View part numbers

Brass terminator closing the flexible hose at the pipe end, for pipe mounted installations.

1 part numbersAISI 316L
View part numbers

Stainless steel flexible hose, M25/M28×1, protecting the heating cable between the pipe insulation and a wall mounted junction box. 2 m length.

1 part numbersAISI 316L
View part numbers

Stainless steel flexible hose, M25/M28×1, protecting the heating cable between the pipe insulation and a wall mounted junction box. 25 m roll.

1 part numbersSilicone
View part numbers

Silicone grommets with pressure nut for high-temperature heating cables in the pipe mounted TEF 1058 box transition unit.

1 part numbers
View part numbers

Spare protective guard in brass for the old-type TEF 2438 and TEF 2439 luminaires. 1.2 kg.

1 part numbersAISI 316L+ Bras
View part numbers

M25 gland and grommet kit that protects a high-temperature heating cable where it enters a wall mounted box, without Raychem termination kit.

3 part numbersII 2 G Ex db eb IIC T5 GbIP 66Stainless steel AISI 316L
View part numbers

Ex de switch box in brushed stainless steel AISI 316L for isolating heat trace cables during maintenance: one lockable 16 A safety switch for one or two parallel heating cables, or three switches for three separate circuits. ATEX and IECEx, IP66. 3 part numbers – select below.

1 part numbersIP 56Halogen
View part numbers

Handheld halogen daylight signalling lamp for Morse signalling ship to ship: 35 W at 12/24 V, 108 900 cd, day range 3.4 km, night 21.4 km, SOS and permanent light, IP56, delivered complete in an ABS case with battery, charger, spare lamps, colour filters and two flush-mount power outlets. DNV MED certified.

1 part numbers
View part numbers

Handheld LED daylight signalling lamp for Morse signalling ship to ship: 5 W at 12/24 V, day range 4 km, night 18 km, SOS and permanent light, IP56, delivered complete in an ABS case with battery, charger, colour filters and two flush-mount power outlets. DNV MED certified.

1 part numbersIP 66/67
View part numbers

Ex eb junction box in stainless steel AISI 316L, pre-configured for connecting one TEF 9980 status light. TEF 1058 size 20, IP66/67, IECEx and ATEX.

1 part numbersIP 66/67
View part numbers

Ex eb junction box in stainless steel AISI 316L, pre-configured for one TEF 9980 status light with the supply looped on to the next lamp. TEF 1058 size 25, IP66/67, IECEx and ATEX.

1 part numbers
View part numbers

R. STAHL 6036 LED tubular light fitting, size 1, with diffuser, blue light 338 lm, 110–240 V, for rescue ladder and escape route lighting.

1 part numbers
View part numbers

R. STAHL 6036 LED tubular light fitting, size 1, with diffuser, blue light 338 lm, 110–240 V, for rescue ladder lighting. Alternative part number to 50301058.

1 part numbers
View part numbers

1500 mm stainless steel AISI 316L shaft connecting a bridge operated TEF 2630 searchlight on the wheelhouse roof to the manoeuvre lever inside.

1 part numbers
View part numbers

Stainless steel hand lever mounted under the wheelhouse roof on the shaft of a bridge operated TEF 2630 searchlight, for turning and tilting the beam.

1 part numbersAISI 316L+ Bras
View part numbers

M20 gland with flexible hose adaptor for PT100 sensor cables of Ø4.5–7.5 mm.

1 part numbersAISI 316L+ Bras
View part numbers

M20 protection kit for PT100 sensor cables of Ø4.5–7.5 mm on wall mounted thermostats.

1 part numbersAISI 316L+ Bras
View part numbers

M25 gland with flexible hose adaptor protecting the PT100 sensor cable (Ø4.5 mm) between pipe and thermostat.

1 part numbersAISI 316L+ Bras
View part numbers

M25 gland with flexible hose adaptor protecting the PT100 sensor cable (Ø8 mm) between pipe and thermostat.

1 part numbers
View part numbers

Spare bracket in stainless steel 316 for mounting the TEF 2870 lantern on a 1" tube. 0.7 kg.

1 part numbers
View part numbers

Teflon (PTFE) strip laid under the heating cable on rough or hot surfaces as a protective layer. 40 × 2 mm, sold per 10 m roll.

1 part numbersStainless Steel
View part numbers

Stainless steel pipe strap for fixing heat trace junction boxes and heating cable accessories to pipes of 1/2" (Ø20–47 mm).

1 part numbersStainless Steel
View part numbers

Stainless steel pipe strap for fixing heat trace junction boxes and heating cable accessories to pipes of 3/4"–1 1/2" (Ø40–90 mm).

1 part numbersStainless Steel
View part numbers

Stainless steel pipe strap for fixing heat trace junction boxes and heating cable accessories to pipes of 2"–8" (Ø60–280 mm).

1 part numbersStainless Steel
View part numbers

Stainless steel pipe strap for fixing heat trace junction boxes and heating cable accessories to pipes of 3"–18" (Ø60–540 mm).

1 part numbers
View part numbers

Set of PVC washers, Ø 32/10 × 1", insulating the TEF 2870 navigation light from its stainless steel mounting bracket.

1 part numbers
View part numbers

Aluminium tape applied over the heating cable to improve heat transfer to the pipe and hold the cable in place. 50 m roll.

4 part numbersII 2 GD Ex 60079-30-1 eb IIC T6 Gb230 V
View part numbers

Self-regulating heating cable for freeze protection and temperature maintenance of pipes and vessels in hazardous areas: 3BTV to 10BTV (9–29 W/m at 10 °C), 230 V, fluoropolymer outer jacket, max. maintain temperature 65 °C and intermittent exposure up to 85 °C. ATEX and IECEx Ex eb IIC T6 Gb. 4 part numbers – select by output below.

1 part numbersEx eb IIC GbIP66277
View part numbers

Cold-applied connection kit for Raychem parallel (self-regulating and power-limiting) heating cables. Ex eb IIC Gb, IP66, max. 277 V.

1 part numbersEx eb IIC GbIP66
View part numbers

Cold-applied termination kit for connecting the heating cable in an M25 gland without a heat gun. Ex eb IIC Gb, IP66.

1 part numbersEx eb IIC GbIP66
View part numbers

Heat-shrink termination kit that prepares the heating cable for connection in an M25 gland. Ex eb IIC Gb, IP66, −55 °C to +110 °C.

1 part numbersII 2 G Ex eb IIC GbIP66110-277
View part numbers

Cold-applied universal end seal mounted above the insulation, so the termination stays accessible for inspection. II 2 G Ex eb IIC Gb, IP66.

1 part numbersEx eb IIC GbIP66110-277
View part numbers

Cold-applied universal end seal for BTV, QTVR and XTVR heating cables, fitted below the insulation. Ex eb IIC Gb, IP66, −55 °C to +56 °C.

1 part numbers
View part numbers

Heat-shrink end seal kit closing the far end of a Raychem BTV or QTVR self-regulating heating cable. Rated −60 °C to +110 °C.

1 part numbers
View part numbers

Heat-shrink end seal kit for the high-temperature Raychem cables XTVR, HTV, KTV and VPL. Rated −60 °C to +260 °C.

1 part numbers
View part numbers

Heat-shrink end seal for the Raychem VPL power-limiting heating cable.

1 part numbersEx eb ib mb [ib] IIC T4 GbIP6690 Vac to 305 Vac
View part numbers

Electronic heat tracing controller with display, alarms and communication, for zone 1 and zone 2. Ex eb ib mb [ib] IIC T4 Gb, IP66, 90–305 V AC, −50 °C to +60 °C.

1 part numbersEx eb ib mb [ib] IIC T4 GbIP6690 Vac to 305 Vac
View part numbers

As Elexant 5010i with an independent safety temperature limiter, for circuits that require a limiter by design (stabilised design or high-temperature cables).

1 part numbers
View part numbers

Electronic thermostat with PT100 line sensing for high-temperature heat tracing, 0–499 °C range, with status light.

1 part numbersSilicone
View part numbers

Silicone protective sleeve for heating cables where they pass sharp edges, cladding or supports. 25 m roll, price per metre.

1 part numbersII 2 GD Ex eb IIC GbPolyamide.
View part numbers

Polyamide M25 cable gland for power cables of Ø8–17.5 mm into Raychem junction boxes. II 2 GD Ex eb IIC Gb.

1 part numbers
View part numbers

High-temperature glass cloth tape for fixing heating cables, rated to 260 °C. 16 m roll. Suitable for stainless steel pipes.

1 part numbers
View part numbers

Glass cloth tape for fixing Raychem self-regulating heating cables to pipes and vessels. 20 m roll. Not for use on stainless steel.

8 part numbersII 2 G Ex eb mb 60079-30-1 IIC T6…T2 Gb230 V
View part numbers

High-temperature self-regulating heating cable for process maintenance up to 205 °C and exposure up to 260 °C: 3HTV to 28HTV (9–92 W/m at 10 °C), 230 V, 5 × 11 mm, HPR heating core with metallic braid and fluoropolymer outer jacket. ATEX and IECEx Ex eb mb IIC T6…T2 Gb. 8 part numbers – select by output below.

1 part numbersIP66750Vpolycarbonate
View part numbers

Chemelex RAYCHEM polycarbonate junction box for heat tracing circuits, 750 V, IP66, −35 to +115 °C. 0.47 kg.

1 part numbersIP66590VPolymer
View part numbers

Polymer universal junction box with three M20 and one M25 entry, IP66, max. 590 V, −55 °C to +55 °C.

1 part numbersEx eb mb IIC GbIP66277
View part numbers

Polymer pipe mounted junction box for up to three Raychem heating cables with cold-applied connections. Ex eb mb IIC Gb, IP66, max. 277 V.

1 part numbersEx eb mb IIC GbIP66110-277
View part numbers

Polymer junction box with integrated cold-applied connection for one Raychem heating cable, mounted directly on the pipe. Ex eb mb IIC Gb, IP66, 110–277 V.

1 part numbersEx eb mb IIC GbIP66110-277
View part numbers

As JBS-100-E, with a green indication light showing that the circuit is energised. Ex eb mb IIC Gb, IP66.

1 part numbersII 2 G Ex eb mb IIC GbIP66480V
View part numbers

Glass-fibre reinforced polymer junction box with four M25 entries for Raychem modular connection systems. II 2 G Ex eb mb IIC Gb, IP66, max. 480 V.

1 part numbersEx eb mb IIC GbIP66277
View part numbers

As JBU-100-E with an internal earth plate for braided cables. Ex eb mb IIC Gb, IP66, max. 277 V.

1 part numbers
View part numbers

Multilingual warning label for VPL power-limiting heating cable installations with stabilised design temperature classification.

1 part numbersEx eb IIC T6 Gb TaAISI 316L
View part numbers

PT100 3-wire temperature sensor for electronic thermostats and controllers in zone 1: Ø6 × 60 mm element, 10 m Ø4.5 mm PTFE cable, M16 Ex e gland, rated to 260 °C at the element.

1 part numbersIP66PTFE (Fluoropolymer)
View part numbers

Chemelex RAYCHEM 3-wire Pt100 sensor with 15 m braided PTFE cable and halogen-free M16 polyamide gland, −50 to +260 °C, for intrinsically safe circuits in Zone 1/21 and Zone 2/22 or non-hazardous areas.

1 part numbers
View part numbers

Chemelex RAYCHEM 3-wire Pt100 sensor with 2 m braided PTFE cable and halogen-free M16 polyamide gland, −50 to +260 °C, for intrinsically safe circuits in Zone 1/21 and Zone 2/22 or non-hazardous areas.

1 part numbersEx eb IIC T6 Gb TaAISI 316L
View part numbers

PT100 3-wire temperature sensor for electronic thermostats and controllers in zone 1: Ø6 × 60 mm element, 25 m Ø4.5 mm PTFE cable, M16 Ex e gland, rated to 260 °C at the element.

1 part numbersIP66PTFE (Fluoropolymer)
View part numbers

PT100 3-wire temperature sensor for electronic thermostats and controllers in zone 1: Ø6 × 60 mm element, 5 m Ø4.8 mm PTFE cable, M16 Ex e gland, rated to 260 °C at the element.

1 part numbersEx eb IIC T6 GbIP66AISI 316L
View part numbers

Chemelex RAYCHEM Ex e Pt100 sensor for high temperature exposure, with 2 m mineral insulated (MI) cable in stainless steel AISI 316L and M16 gland, IP66.

1 part numbersEx eb IIC T6 GbIP66AISI 316L
View part numbers

Chemelex RAYCHEM Ex e Pt100 sensor for high temperature exposure, with mineral insulated (MI) cable and junction box, stainless steel AISI 316L, IP66.

1 part numbersGb Ex e mb ib IICIP66100 to 254V
View part numbers

Chemelex RAYCHEM NGC-20 single-circuit electronic controller in a glass-fibre reinforced polymer enclosure for hazardous areas, −40 to +60 °C, 50/60 Hz. 3.7 kg.

1 part numbersGb Ex e mb ib IICIP66101 to 254V
View part numbers

Chemelex RAYCHEM NGC-20 single-circuit electronic controller with independent temperature limiter, in a glass-fibre reinforced polymer enclosure for hazardous areas, −40 to +60 °C, 50/60 Hz. 3.7 kg.

3 part numbersII 2 GD Ex 60079-30-1 eb IIC T4 Gb230 V
View part numbers

High-output self-regulating heating cable for freeze protection and temperature maintenance of large pipes and vessels in hazardous areas: 10QTVR to 20QTVR (38–64 W/m at 10 °C), 230 V, fluoropolymer outer jacket, max. maintain temperature 110 °C. ATEX and IECEx Ex eb IIC T4 Gb. 3 part numbers – select by output below.

1 part numbersEx db IIC T6 GbIP66480V
View part numbers

Mechanical capillary thermostat in cast aluminium for switching heating cable circuits in hazardous areas. Ex db IIC T6 Gb, IP66, max. 480 V, −40 °C to +60 °C.

1 part numbersEx eb IIC GbIP66254
View part numbers

Cold-applied universal in-line splice for Raychem self-regulating heating cables. Ex eb IIC Gb, IP66, max. 254 V.

1 part numbers
View part numbers

Heat-shrink in-line splice joining two lengths of BTV or QTVR (and TLT) heating cable under the insulation. −60 °C to +110 °C.

1 part numbers
View part numbers

Heat-shrink in-line splice for the high-temperature Raychem cables XTVR, KTV, HTV and VPL.

1 part numbers
View part numbers

Cold-applied junction box for splicing or tee-connecting Raychem heating cables under the insulation, with crimp connectors.

1 part numbers
View part numbers

Chemelex RAYCHEM TLT self-regulating heating cable, 90 W/m at 220–240 V, 5 × 15 mm, for winterization of metal walkways and decks on vessels in non-hazardous areas. Sold per metre.

4 part numbersII 2 G Ex 60079-30-1 eb IIC T* Gb230 V
View part numbers

Power-limiting heating cable for high-temperature process maintenance up to 235 °C and exposure up to 260 °C: 5VPL to 20VPL (15–61 W/m), 230 V, 5 × 11 mm, fluoropolymer outer jacket, low start-up current and cut-to-length installation with overlap capability. ATEX and IECEx Ex eb IIC Gb. 4 part numbers – select by output below.

7 part numbersII 2 G Ex 60079-30-1 eb IIC T* Gb230 V
View part numbers

Self-regulating heating cable for process temperature maintenance in demanding industrial applications: 3XTVR to 20XTVR (9–63 W/m at 10 °C), 230 V, 5 × 11 mm, fluoropolymer outer jacket, max. maintain temperature 150 °C and intermittent exposure up to 250 °C. ATEX and IECEx Ex eb IIC Gb with stabilised design T-rating. 7 part numbers – select by output below. Replaces the earlier XTV2-CT-T3 sizes.

1 part numbers
View part numbers

Stainless steel 316L screen fitted over the tubular rescue ladder light to direct the blue light towards the ladder and the water and shield it from the deck.

1 part numbers
View part numbers

Stainless steel pedestal, 300 mm high, raising a direct or bridge operated TEF 2620/2630 searchlight above the deck or wheelhouse roof.