Marine · 64 products · 5 product groups
Marine Lighting & Control Systems for Safe and Reliable Shipping
Our Marine portfolio is trusted worldwide for safe and efficient shipping operations.
See the area →Solutions
Ex-certified equipment, heat tracing systems and marine lighting, designed and built at our own factory in Norway. Choose an area to see the product groups, or go straight to downloads for brochures and certificates.
Marine · 64 products · 5 product groups
Our Marine portfolio is trusted worldwide for safe and efficient shipping operations.
See the area →
Energy · 158 products · 10 product groups
There are few higher-stakes environments when it comes to safety and reliability than the oil and gas sector.
Aviation · 17 products · 7 product groups
Our Aviation solutions provide compliant, high-performance lighting and control systems for helidecks, both offshore and onshore, as well as hospitals and other critical infrastructure.
See the area →How we help
Sizing, lighting and heat loss calculations, documentation for class and commissioning.
Designed, built and tested under one roof, with short delivery times and room for changes.
Datasheets, Ex certificates, declarations of conformity and STEP files are on every product page.
Send us the drawings or the equipment list and we propose a solution, part numbers and documentation.
Stainless steel pedestal, 600 mm high, for remote controlled TEF 2650 Commander searchlights. 8 kg.
Searchlights
Searchlight Pedestal H=800 mm – stainless steel, for direct and bridge operated TEF 2620/2630
Stainless steel pedestal, 800 mm high, for direct or bridge operated TEF 2620/2630 searchlights where the beam must clear rails and deck equipment.
750 mm stainless steel AISI 316L shaft connecting a bridge operated TEF 2630 searchlight on the wheelhouse roof to the manoeuvre lever inside.
Interface module for the xenon power control units of the TEF 2650 xenon searchlights, 1600 and 2000 W version. 9 kg.
Accessories
Stainless steel splice joining two lengths of the AISI 316 flexible hose. M28×1.
Stainless steel bracket with engraved Trafolyte tag for marking heat trace junction boxes and circuits.
Junction & Terminal Boxes
TEF 1054 Arctic Junction Box for de-icing – 3 entries, stainless steel
Non-Ex TEF 1054 junction box prepared for heat tracing and de-icing circuits in arctic conditions, with three cable entries. 1.1 kg. Manual TUM1026.
Junction & Terminal Boxes
TEF 1054 Arctic Junction Box for de-icing – 5 entries, stainless steel
Non-Ex TEF 1054 junction box prepared for heat tracing and de-icing circuits in arctic conditions, with five cable entries. 1.2 kg. Manual TUM1026.
Mechanical thermostat for heat tracing in hazardous areas: 1 m capillary tube, 16 A change-over switch, built on the TEF 1058 pipe mounted heat trace junction box in electropolished AISI 316L. Three setting ranges from −20 to +190 °C. ATEX and IECEx, IP66/67. 3 part numbers – select the range below.
Mechanical thermostat for heat tracing in hazardous areas: 1 m capillary tube, 16 A change-over switch, built on the TEF 1058 wall mounted heat trace junction box in electropolished AISI 316L. Three setting ranges from −20 to +190 °C. ATEX and IECEx, IP66/67. 3 part numbers – select the range below.
Junction & Terminal Boxes
Explosion-protected control station in the TEF 1058 stainless steel enclosure with one emergency stop with NO/NC contacts and a protective cover against unintended operation, for Zone 1, Zone 2 and safe areas. IP66/67, −40 °C to +50 °C, 1.2 kg.
Junction & Terminal Boxes
TEF 1058 Control Station Ex eb – 1 × emergency stop NO/NC, stainless steel AISI 316L
Explosion-protected control station in the TEF 1058 stainless steel enclosure with one emergency stop with NO/NC contacts, for Zone 1, Zone 2 and safe areas. IP66/67, −40 °C to +50 °C, 1.2 kg.
Junction & Terminal Boxes
TEF 1058 Control Station Ex eb – 1 × pushbutton NO/NC, stainless steel AISI 316L
Explosion-protected control station in the TEF 1058 stainless steel enclosure with one pushbutton with NO/NC contacts, for Zone 1, Zone 2 and safe areas. IP66/67, −40 °C to +50 °C, 1.2 kg.
Junction & Terminal Boxes
TEF 1058 Control Station Ex eb – 2 × pushbutton NO/NC, stainless steel AISI 316L
Explosion-protected control station in the TEF 1058 stainless steel enclosure with two pushbuttons with NO/NC contacts, for Zone 1, Zone 2 and safe areas. IP66/67, −40 °C to +50 °C, 1.2 kg.
End termination for self-regulating heating cables in stainless steel AISI 316L with an indicator lamp (12–254 V AC/DC) that shows the circuit is live. Built on the TEF 1058 junction box, ATEX and IECEx Ex eb IIC T5 Gb, IP66, zone 1, zone 2 and safe area. Two part numbers: pipe mounted or wall mounted.
On-line heat trace junction box in stainless steel AISI 316L, mounted directly on the traced pipe with a transition unit for the heating cable. Small box for 2 heating cables, large box for 3, drilled or complete with glands. ATEX and IECEx Ex eb IIC T5 Gb, IP66/67. 8 part numbers – select by size below.
Off-line heat trace junction box in stainless steel AISI 316L for wall mounting, with the heating cables brought in through connection kits and flexible conduit. Small box for 2 heating cables, large box for 3, drilled or complete with glands. ATEX and IECEx Ex eb IIC T5 Gb, IP66/67. 9 part numbers – select by size below.
Junction & Terminal Boxes
TEF 1058 Junction Box Ex eb – stainless steel AISI 316L, size 05 to 45
Stainless steel junction box for zone 1, zone 2 and safe area, certified ATEX and IECEx as Ex eb IIC T5 Gb, IP66/67. Nine sizes from 05 to 45 for conductors up to 16 mm², empty or with terminal rail and PE bus bar, bright chemical dip or electropolished, arctic version to −60 °C. 47 part numbers – select by size below.
Pre-equipped Ex eb distribution box in stainless steel AISI 316L for local field power to up to five heat tracing circuits: ten terminals linked 5+5, PE earth bar, entries with temporary plugs and label kit. Terminals in 6, 10 or 16 mm². ATEX and IECEx, IP66/67. 3 part numbers – select by terminal size below.
Pre-equipped stainless steel junction box for local power distribution in hazardous areas: terminals, PE bus bar and pre-drilled entries with temporary plugs, from 16 A single-phase to 35 A and three-phase 400 V distribution. ATEX and IECEx Ex eb IIC T5 Gb, IP66/67. 10 part numbers – select by size and load below.
Electronic heat trace thermostat with PT100 sensor and 3 °C hysteresis for precise temperature maintenance in hazardous areas, built on the TEF 1058 heat trace junction box in AISI 316L. Pipe mounted for three heating cables or wall mounted for two, set points to +199 °C or +499 °C. ATEX, IP66. 3 part numbers – select below.
Ex eb high voltage junction boxes in stainless steel AISI 316L for 1.1 to 11 kV: A-block solutions with terminals up to 100 A, and copper bar solutions type R, C and G up to 2100 A. ATEX and IECEx, IP66, customised sizes on request. 34 standard configurations – select by system and voltage below.
Technical Lighting
TEF 2440 LED Luminaire – clear globe, 1 250 lm, 5000 K, 230 V AC, IP66/67
General-purpose LED luminaire in the TEF 2440 housing: acid-proof stainless steel base, clear polycarbonate globe, 1 250 lm at 5000 K, max. 10 W, 230 V AC 50/60 Hz, IP66/67, −40 °C to +45 °C.
Red omni-directional LED obstruction light for cranes, masts and structures in safe areas: >32 cd to ICAO Annex 14 Vol. 1 Ch. 6 Type B, acid-proof stainless steel with red polycarbonate globe, max. 10 W, IP66. 230 V AC or 24 V AC/DC – select below.
Helideck perimeter light for safe areas: five LEDs in a polycarbonate globe on acid-proof stainless steel, >30 cd green to ICAO Annex 14 Vol. II and CAP 437, max. 10 W, IP66, under 150 mm high. Green in 100–230 V AC or 24 V AC/DC, and red in 100–230 V AC – select below.
Technical Lighting
TEF 2457 Luminaire – brass, without globe and regulator, G4 12/24 V, IP56
Brass luminaire body of the TEF 2457 with G4 lamp holder for 12/24 V AC/DC, max. 25 W, IP56, delivered without globe and regulator. 1 kg.
Explosion-protected red obstruction light in hot-forged brass with polycarbonate dome: Ex eb mb op is IIC T5 Gb, encapsulated electronics, IP66/67, −55 to +55 °C. 32 cd (ICAO Type B) or 10 cd (Type A), AC or 24 V DC, with IR LEDs for night vision on request. Six versions – select below.
Explosion-protected helideck perimeter light in hot-forged brass with glass dome: Ex eb mb op is IIC T5 Gb, encapsulated electronics, >30 cd green to ICAO Annex 14 and CAP 437, 4–5 W, IP66/67, −55 to +55 °C. 100–254 V AC or 24 V DC – select below.
Searchlights
The TEF 2613 multi-searchlight panel mounted in a polycarbonate enclosure for surface mounting outside the bridge console: controls up to eight TEF 2650 Commander searchlights over RS-485, 24 V DC, IP56.
Searchlights
TEF 2618 Radio Control Unit for Commander searchlights – single channel, 1 remote control
Handheld radio control for up to eight TEF 2650 Commander searchlights: watertight IP54 panel with 30 h battery, 500 m range, 69 channels at 433 MHz, and a cabinet on the searchlight network. Single channel with one remote.
Direct operated stainless steel halogen searchlight, 1000 W (305 mm mirror) or 2000 W (450 mm mirror), IP56, TEF 2610 panel. Discontinued 31 March 2027, orders until 31 December 2026; recommended replacement TEF 2650 Commander. Two part numbers – select below.
Bridge operated stainless steel halogen searchlight aimed by shaft and lever from the wheelhouse: 250 W 24 V, 1000 W or 2000 W, without or with 300/800 mm pedestal, IP56. Discontinued 31 March 2027, orders until 31 December 2026; recommended replacement TEF 2650 Commander. Nine part numbers – select below.
Searchlights
TEF 2650 Xenon Searchlight Interface Module (SIM) – relay control of 1 to 8 xenon power supplies
DIN-rail module that listens to the Commander RS-485 network and closes one of eight relays when the matching xenon searchlight is switched on, feeding 230 V AC to its power supply without a separate cable from the searchlight.
Ready-to-install helideck lights control for safe areas: pre-wired IP66 enclosure with 8 outgoing circuits and a push-button panel for the bridge on RS-485, up to 7 panels. Dual power with automatic changeover to DNV F503, Naut-OSV bridge alarm, optional NMEA-0183 gateway. Part number 4500303.
Aviation
TEF 4600 Integrated Helideck Light Control – one cabinet for all helideck lights, Zone 1 or non-Ex
All helideck lighting controlled and supervised from one cabinet with a pre-programmed touch panel: perimeter, floodlights, Circle & H, obstruction, windsock and status lights. Dual 230 V AC supply with automatic changeover, Ethernet and Modbus TCP/IP, optional HMS and SCADA integration. Non-Ex or Zone 1 with EXicom MT-498 panel. Ten configurations – select below.
Accessories
Stainless steel protector fitted where the heating cable passes a cladding edge, preventing the sheet metal from cutting into the cable.
Accessories
TEF 7211-A Flange Crossing Protector with silicone sleeve – flange size 27–40 mm, AISI 316
Stainless steel bridge with silicone protection sleeve that carries the heating cable over a flange of 27–40 mm without kinking or chafing.
Accessories
TEF 7211-B Flange Crossing Protector with silicone sleeve – flange size 37–50 mm, AISI 316
Stainless steel bridge with silicone protection sleeve that carries the heating cable over a flange of 37–50 mm without kinking or chafing.
Accessories
TEF 7211-C Flange Crossing Protector with silicone sleeve – flange size 50–95 mm, AISI 316
Stainless steel bridge with silicone protection sleeve that carries the heating cable over a flange of 50–95 mm without kinking or chafing.
Accessories
TEF 7211-D Flange Crossing Protector with silicone sleeve – flange size 95–140 mm, AISI 316
Stainless steel bridge with silicone protection sleeve that carries the heating cable over a flange of 95–140 mm without kinking or chafing.
Stainless steel exit plate that leads the heating cable out through the insulation cladding with a single bend, M25.
Accessories
TEF 7730 Cladding Penetration System M25 for HT cables 5×11/5×13/5×15 – no termination kit
Complete cladding penetration for high-temperature heating cables: M25 gland, cladding penetration fitting and grommets for 5×11, 5×13 and 5×15 mm cables.
Accessories
Cladding penetration fitting with M28×1 entry for the flexible hose, letting the protected heating cable pass through the insulation cladding.
Stainless steel exit plate with double bend, M25, for leading the heating cable out through the cladding parallel to the pipe.
Accessories
Mounting set for fitting a heat trace junction box across two parallel pipes.
Stainless steel spacer that lifts the pipe mounted TEF 1058 heat trace junction box or end seal away from a hot pipe.
Stainless steel spacer for the wall mounted TEF 1058 heat trace junction box on hot lines.
Enclosure Heaters
TEF 9202 Composite Enclosure Heater Ex – 50 and 100 W, 120/240 V
Lightweight self-regulating Ex enclosure heater in flame-retardant composite for Zone 1, Zone 2 and safe area, 0.56–0.76 kg, with 1.5 m flying lead. T4 in 120 or 240 V for IP54 enclosures, or T3 with IP66 in 240 V. 6 part numbers – select below.
Heat Tracing Solutions
TEF 9204 Stair Heater Enclosure 161 × 662 mm – 200 W, for QTVR heating cable, AISI 316L
Acid-proof stainless steel enclosure mounted under an outdoor step, holding six loops of QTVR self-regulating heating cable for about 200 W per step. Heating cable ordered separately.
Heat Tracing Solutions
TEF 9204 Stair Heater Enclosure 161 × 762 mm – 230 W, for QTVR heating cable, AISI 316L
Acid-proof stainless steel enclosure mounted under an outdoor step, holding six loops of QTVR self-regulating heating cable for about 230 W per step. Heating cable ordered separately.
Weld-in socket in acid-proof stainless steel AISI 316 for joining two Ø 27 mm conduit pipes carrying heating or power cable, with a strong watertight weld and no burr inside the pipe.
Weld-on entry kit that takes a self-regulating heating cable (5 × 11, 5 × 13 or 5 × 15 mm) watertight into a hand rail, with integrated cable gland and silicone grommets. 0.4 kg.
Compact indoor control cabinet for the TRANBERG® IMT Circle & H helideck lighting: indicators and control buttons in the door, direct connection of all Circle & H circuits, 230 V AC, IP66, provision for an optional remote Ex panel.
Helideck windsock in AISI 316L and brass with one spare sleeve, in four versions: without lights, with obstruction lights, internally lit, or with IR for night vision. Ex certified lit versions. 20 variants – select by lighting, size and voltage below.
Explosion-protected LED helideck floodlight in marine-grade anodised aluminium: 2 400 lm, 17 500 cd, 40 W, IP66/67, DALI, Ex eb mb / Ex tb for zones 1, 2, 21 and 22. ICAO Annex 14, CAP 437 and NORSOK. 100–240 V AC or 24 V DC, low or high bracket – select below.
LED helideck floodlight for safe areas in marine-grade anodised aluminium: 2 400 lm, 17 500 cd, max. 40 W, 100–240 V AC, IP66, DALI, sealed for life. Same optics and housing as the Ex-certified TEF 9975. ICAO Annex 14, CAP 437 and NORSOK.
Flashing red status light system to CAP 437, NORMAM-27 and the MODU Code: main light min. 700 cd, low-dome repeater 16–60 cd, both fully monitored with our helideck control. Seawater-resistant aluminium and tempered glass, 16–32 V DC, IP66/67, NVG compatible, Ex db op is. Main or repeater – select below.
Small Ex-certified outdoor cabinet connected to the TEF 9980 control panel, giving remote control and fault indication of up to two main lights and two repeater lights from Zone 1, Zone 2 or safe area. IECEx and ATEX, CAP 437.
Fixed 100 Ω reference resistor with heat-shrink sleeve, simulating a PT100 sensor at 0 °C for testing the ThermoConnect TTC controller and limiter.
LED lighting system marking the TD/PM circle and the H on the helideck to CAP 437 and ICAO Annex 14. Sealed Ex fixtures (Zone 1) in marine-grade aluminium, 24 V DC, IP66/67, interlocking design and 60 % fewer holes in the deck. Stand-alone or integrated with TEF 4600.
TRANBERG® Smart Thermostat
TRANBERG® ThermoConnect TTC2 – Ex heat-tracing controller and controller/limiter
The current 16 A generation of ThermoConnect: Chemelex RAYCHEM Elexant 5010i controller or SIL 2 controller/limiter in a STAHL 8150/5 stainless steel enclosure for Zone 1, Zone 2 and safe area, Modbus RTU, alarms and automated heating-cable check, with or without a 16 A safety switch. Four part numbers – select below.
Technical Lighting
Transformer with Mounting Bracket for TEF 9964 – 230/254 V AC
Replacement transformer with mounting bracket for the TEF 9964 luminaire, 230/254 V AC input. 1.55 kg.
TEF 1061 Exe Fiber Splicebox
TEF 1061-3 Ex e Splice Box for Optical Fibre – 12 to 96 FO, stainless steel
Ex e splice box for single-mode and multi-mode optical fibre in Zone 1 and Zone 2, brushed stainless steel AISI 316L, IP66, T4. Four sizes for 12, 24, 48 or 96 fibres – select below.
TRANBERG® Smart Thermostat
TRANBERG® ThermoConnect TTC – Ex heat-tracing controller and controller/limiter
Electronic heat-tracing controllers and controller/limiters (IEC 61508 SIL 2) in a STAHL 8150 stainless steel enclosure for Zone 1, Zone 2 and safe area. TTC 20 A with the Raychem NGC-20, also as double unit and with safety switch, wireless versions with Trusted Wireless or Wireless HART, and repeater modules. 13 part numbers – select below.
Junction & Terminal Boxes
TEF 1054 Junction Box for Industry and Marine – stainless steel AISI 316L, size 05 to 45
Stainless steel junction box for safe areas in industry and marine use, same nine sizes as the Ex-certified TEF 1058: empty or with terminal rail and PE bus bar, bright chemical dip or electropolished, EPDM gasket, IP66/67. 35 part numbers – select by size below.
LED floodlight for area lighting on vessels: typ. 30 000 lumen at max. 220 W, IP66/67, seawater-resistant C5M powder-coated aluminium housing with glass front, DALI included and Phoenix QPD quick plugs. Narrow, medium or wide light distribution in 2200 K, 4000 K or 5000 K. 9 part numbers – select by colour temperature and beam below.
Searchlights
Plug-and-play LED unit that upgrades an existing TEF 2650 (and TEF 26x0 450 mm drum) halogen searchlight to the LED51: 84 LEDs, 30 000 lm, 4.75 Mcd, 400 W at 230 V, no lamp changes. Keeps the drum, motors and network control.
Searchlight Control Panels
TEF 2610 Searchlight Control Panel – for TEF 2620 and TEF 2630 (discontinued 2027)
Flush-mounted master panel for one direct or bridge operated TEF 2620/2630 searchlight: lamp power, ignition and focus wide/narrow on large switches, 230 V AC, IP20. Phased out together with the TEF 2620/2630 on 31 March 2027; orders until 31 December 2026.
Searchlight Control Panels
TEF 2612 Commander Searchlight Control Panel – one TEF 2650 searchlight, RS-485
Flush-mounted panel controlling one TEF 2650 Commander searchlight over the RS-485 network: light, ignition, on/standby, narrow/wide, dim, fast/slow, group and home position. 24 V DC, IP20, 168 × 96 × 55 mm, up to 16 panels on the network.
Searchlight Control Panels
TEF 2613 Commander Searchlight Control Panel – up to 8 TEF 2650 searchlights, RS-485
Flush-mounted multi-searchlight panel for up to eight TEF 2650 Commander searchlights (halogen, xenon or LED) over RS-485: select searchlight 1–8, light, ignition, on/standby, narrow/wide, dim, fast/slow, group and home. 24 V DC, IP22, 168 × 96 × 55 mm.
Enclosure Heaters
TEF 9209 Enclosure Heater Ex T4, 120 V – 50 to 600 W, stainless steel
Self-regulating Ex enclosure heater for 120 V systems, stainless steel AISI 316L, temperature class T4, for enclosures rated IP54 or higher in Zone 1, Zone 2 and safe area. 50–600 W with flying lead, junction box, or junction box and ambient thermostat (+5 or +15 °C). 16 part numbers – select by connection and output below.
Encapsulated Ex mb bimetal ambient thermostat in chromium-plated brass for Zone 1, Zone 2 and safe area: NO 16 A contact, M25 entry, −50 to +50 °C. Two switching ranges, +3/+12 °C and +10/+20 °C – select below.
Energy
TEF 9179 Connection Kit, pipe mounted – Raychem heating cables 5 × 11 / 5 × 15 mm, hot or cold
Connection kit for Raychem self-regulating heating cables into the pipe mounted TEF 1058 heat trace junction box: brass compression nut M28×1 with silicone grommet and AISI 316 washer, with Raychem C25 termination in hot (heat shrink) or cold-applied version, or without. 7 part numbers – select by cable size and termination below.
Heat Tracing Solutions
TEF 9179 Connection Kit, wall mounted – Raychem heating cables 5 × 11 / 5 × 15 mm, hot or cold
Connection kit for Raychem self-regulating heating cables into the wall mounted TEF 1058 heat trace junction box: transition unit M25 with cladding exit plate, silicone grommets, hose adaptors and M25 gland, with Raychem C25 termination in hot (heat shrink) or cold-applied version, or without. 7 part numbers – select by cable size and termination below.
Cable Glands, Stopping Plugs & Adaptors
Ex e / Ex d cable gland in brass with patented 100 % pull-out gasket, Zone 1, Zone 2 and safe area. 35 variants – select by cable diameter below.
Cable Glands, Stopping Plugs & Adaptors
TEF D620 Ex e/Ex d Cable Gland – Stainless Steel AISI 316, M16–M40
Ex e / Ex d cable gland in stainless steel AISI 316 with patented 100 % pull-out gasket, Zone 1, Zone 2 and safe area. 26 variants – select by cable diameter below.
Cable Glands, Stopping Plugs & Adaptors
Ex e cable gland in brass for unarmoured and braided cables, Zone 1, Zone 2 and safe area. 85 variants – select by cable diameter below.
Cable Glands, Stopping Plugs & Adaptors
TEF E204/622 Ex e Cable Gland – Stainless Steel AISI 316, M16–M90
Ex e cable gland in stainless steel AISI 316 for unarmoured and braided cables, Zone 1, Zone 2 and safe area. 70 variants – select by cable diameter below.
Cable Glands, Stopping Plugs & Adaptors
Ex e cable gland in brass with PTFE gasket to the enclosure, for unarmoured and braided cables in Zone 1, Zone 2 and safe area. 45 variants – select by cable diameter below.
Cable Glands, Stopping Plugs & Adaptors
Double-seal Ex d / Ex e cable gland for armoured cables, ATEX and IECEx certified. 13 brass sizes – select by cable diameter below.
Commander Utility Operator Panel
TEF 4500 Commander Utility Modules – gateway, relay output, I/O and Ex local panel
DIN-rail output and interface modules for the Commander Utility network: gateway to VDR/SCADA, 24-output relay module, 24 I/O module and Ex local helideck panel. 4 parts – select by function below.
Commander Utility Operator Panel
TEF 4500 Commander Utility Operator Panels – 21 to 53 buttons, helideck panels and foils
Custom-built, backlit operator panels for deck, floodlight, helideck, heating and pump control, 3 to 7 columns of buttons, plus helideck panels and replacement Lexan foils. 14 parts – select by panel size below.
Cable Glands, Stopping Plugs & Adaptors
Ex d / Ex e stopping plug in brass for closing unused metric entries, 15 mm thread, O-ring, IP66/67. 10 sizes – select by entry thread below.
Cable Glands, Stopping Plugs & Adaptors
TEF 793/650 Ex d/Ex e Stopping Plug – Stainless Steel AISI 316, M16–M100
Ex d / Ex e stopping plug in stainless steel AISI 316 for closing unused metric entries, 15 mm thread, O-ring, IP66/67. 10 sizes – select by entry thread below.
Cable Glands, Stopping Plugs & Adaptors
Ex d / Ex e stopping plug in brass with NPT thread for closing unused entries, IP54. 9 sizes – select by entry thread below.
Cable Glands, Stopping Plugs & Adaptors
TEF 793/652 Ex d/Ex e Stopping Plug – Stainless Steel AISI 316, NPT 3/8″–3″
Ex d / Ex e stopping plug in stainless steel AISI 316 with NPT thread for closing unused entries, IP54. 9 sizes – select by entry thread below.