Energy

Cable Glands, Stopping Plugs & Adaptors

Explosion-Protected Cable Glands and Accessories for Every Installation

R. STAHL TRANBERG offers a comprehensive range of cable glands, stopping plugs, and adaptors designed to facilitate the safe and secure passage of cables into enclosures, particularly in hazardous environments.

Read more

These products are engineered to meet the stringent requirements of various enclosure types and cable specifications, ensuring optimal performance and safety.

Cable Glands, Stopping Plugs & Adaptors

Cable Glands, Stopping Plugs & Adaptors

TEF D620 Ex e/Ex d Cable Gland – Brass, M16–M63

35 part numbersEx eb/ed IICIP 66/67Brass
View part numbers

Ex e / Ex d cable gland in brass with patented 100 % pull-out gasket, Zone 1, Zone 2 and safe area. 35 variants – select by cable diameter below.

26 part numbersEx eb/ed IICIP 66/67AISI316
View part numbers

Ex e / Ex d cable gland in stainless steel AISI 316 with patented 100 % pull-out gasket, Zone 1, Zone 2 and safe area. 26 variants – select by cable diameter below.

Cable Glands, Stopping Plugs & Adaptors

TEF E204/622 Ex e Cable Gland – Brass, M16–M90

85 part numbersEx eb IICIP 66/67Brass
View part numbers

Ex e cable gland in brass for unarmoured and braided cables, Zone 1, Zone 2 and safe area. 85 variants – select by cable diameter below.

70 part numbersEx eb IICIP 66/67AISI316
View part numbers

Ex e cable gland in stainless steel AISI 316 for unarmoured and braided cables, Zone 1, Zone 2 and safe area. 70 variants – select by cable diameter below.

45 part numbersEx eb IICIP 66/67Brass
View part numbers

Ex e cable gland in brass with PTFE gasket to the enclosure, for unarmoured and braided cables in Zone 1, Zone 2 and safe area. 45 variants – select by cable diameter below.

Cable Glands, Stopping Plugs & Adaptors

CMP Triton T3CDS Cable Gland – Brass, M20–M75

13 part numbersBrass
View part numbers

Double-seal Ex d / Ex e cable gland for armoured cables, ATEX and IECEx certified. 13 brass sizes – select by cable diameter below.

Cable Glands, Stopping Plugs & Adaptors

TEF 793/650 Ex d/Ex e Stopping Plug – Brass, M16–M100

10 part numbersEx db/eb IICIP 66/67Brass
View part numbers

Ex d / Ex e stopping plug in brass for closing unused metric entries, 15 mm thread, O-ring, IP66/67. 10 sizes – select by entry thread below.

10 part numbersEx db/eb IICIP 66/67AISI316
View part numbers

Ex d / Ex e stopping plug in stainless steel AISI 316 for closing unused metric entries, 15 mm thread, O-ring, IP66/67. 10 sizes – select by entry thread below.

9 part numbersEx db/eb IICIP 54Brass
View part numbers

Ex d / Ex e stopping plug in brass with NPT thread for closing unused entries, IP54. 9 sizes – select by entry thread below.

9 part numbersEx db/eb IICIP 54AISI316
View part numbers

Ex d / Ex e stopping plug in stainless steel AISI 316 with NPT thread for closing unused entries, IP54. 9 sizes – select by entry thread below.

Cable Glands, Stopping Plugs & Adaptors

TEF 794/650 Ex e Stopping Plug – Brass, 9 mm, M16–M32

9 part numbersEx eb IICIP 66/67Brass
View part numbers

Ex e stopping plug in brass with short 9 mm thread, O-ring, IP66/67, with or without lock nut. 9 variants – select by entry thread below.

8 part numbersEx eb IICIP 66/67AISI316
View part numbers

Ex e stopping plug in stainless steel AISI 316 with short 9 mm thread, O-ring, IP66/67, with or without lock nut. 8 variants – select by entry thread below.

43 part numbersEx eb/ed IICIP 54Brass
View part numbers

Ex e / Ex d thread adaptor in brass with NPT male thread, for fitting a cable gland in a different entry size, Zone 1, Zone 2 and safe area. 43 variants – select by male and female thread below.

38 part numbersEx eb/ed IICIP 66/67AISI316
View part numbers

Ex e / Ex d thread adaptor in stainless steel AISI 316 with metric male thread, for fitting a cable gland in a different entry size, Zone 1, Zone 2 and safe area. 38 variants – select by male and female thread below.

43 part numbersEx eb/ed IICIP 54AISI316
View part numbers

Ex e / Ex d thread adaptor in stainless steel AISI 316 with NPT male thread, for fitting a cable gland in a different entry size, Zone 1, Zone 2 and safe area. 43 variants – select by male and female thread below.

6 part numbersEx eb IICIP 66/67Brass
View part numbers

Fixed 90° Ex e angle adaptor in brass with metric male thread and metric or NPT female thread, O-ring, IP66/67. 6 variants – select by thread pair below.

6 part numbersEx eb IICIP 66/67AISI316
View part numbers

Fixed 90° Ex e angle adaptor in stainless steel AISI 316 with metric male thread and metric or NPT female thread, O-ring, IP66/67. 6 variants – select by thread pair below.

3 part numbersEx eb IICIP 66/67Brass
View part numbers

Adjustable Ex e angle adaptor in brass with swivel, metric male and female thread, O-ring, IP66/67. 3 sizes – select by thread size below.

3 part numbersEx eb IICIP 66/67AISI316
View part numbers

Adjustable Ex e angle adaptor in stainless steel AISI 316 with swivel, metric male and female thread, O-ring, IP66/67. 3 sizes – select by thread size below.

3 part numbersIP66Brass
View part numbers

Ex eb / Ex tb drain plug and breather in brass for junction boxes and enclosures in Zone 1, Zone 2, 21 and 22. IP66, −60 to +130 °C, M25 with 9 or 15 mm entry, matching lock nut. Select below.

7 part numbersBrass
View part numbers

Brass insert that blanks an unused E204/622 or E205/624 cable gland while keeping its Ex e certification and IP66/67 rating. Seven sizes by sealing ring code A1–E2, with STEP files – select below.

18 part numbers
View part numbers

Heavy-duty BSP cable entries for safe areas from our own factory: TEF 714 cable gland with lock nut, TEF 716 stuffing flange for bolting to thin bulkheads, and TEF 718 terminal tube for pipe ends. 1/2", 3/4" and 1" for 8–24 mm cable, brass or aluminium, with neoprene grommet and two pressure rings. 18 part numbers – select below.

32 part numbers
View part numbers

Rapid-set compound barrier glands from CMP for Ex d and Ex e enclosures: PX2K for armoured SWA cable and PXSS2K for unarmoured and braided cable, M20 to M75 in brass, armoured M20–M40 also in nickel plated brass. 32 part numbers – select by thread and cable diameter below.

Cable Glands
Cable glands are essential components that provide secure entry points for cables into electrical enclosures, maintaining the enclosure's integrity and safety. R. STAHL TRANBERG's cable glands are available in various designs and materials, including brass and stainless steel (AISI316), to accommodate different application needs. Notable models include:​
TRANBERG® CABLE GLAND TEF E204-622: Suitable for Zone 1, Zone 2, and Safe Area applications, this cable gland is made from either brass or stainless steel AISI316. It features Exe IP66/67 protection, metric threads (x 1.5mm), and an O-ring entry seal for enhanced safety and reliability. ​
TRANBERG® CABLE GLAND TEF D620: Designed for Zone 1, Zone 2, and Safe Area environments, this gland is constructed from stainless steel AISI316. It offers Exe/Exd protection with 100% pull-out force compliance, adhering fully to IEC/EN 60079-0 cable retention requirements. The gland includes an O-ring entry seal and imposes no special conditions for safe use. ​
Stopping Plugs and Adaptors
In addition to cable glands, we provide various stopping plugs and adaptors to complement their cable management solutions. These accessories are designed to ensure compatibility and maintain the integrity of enclosures when modifications or customizations are necessary. ​
Accessories
To support the installation and maintenance of cable glands and related components, R. STAHL TRANBERG offers a range of accessories, including:​
  • Earth Tags: Provide a reliable earth connection for cable glands, enhancing safety in electrical installations.​
  • Insert Stopping Plugs: Used to seal unused cable entries, maintaining the enclosure's ingress protection rating.​
  • Breather/Drain Plugs: Assist in preventing condensation buildup within enclosures by allowing ventilation and drainage.​
  • Adapters & Reducers: Enable the connection of cable glands to enclosures with differing thread sizes, ensuring a secure fit.​
  • Lock Nuts: Secure cable glands and accessories in place, preventing loosening due to vibration or other factors.​
These accessories are integral to achieving a complete and secure cable management system, tailored to the specific requirements of each installation.